Design
- Direct current regeneration
- Total dissolved solids (TDS) up to 500 mg/l
- Quick assembly and short commissioning time
- Small setup space requirement
- Simple operation and maintenance
- Reliable operating mode with product flow value monitoring
- Automatic regeneration
- The valve model enables optimal operation and good
- back-flushing and regeneration flows
Components
- GRP pressure tank
- Cation and anion resin
- Central control valves
- Microprocessor control
- Dosing tank including collecting tray
- Regeneration fittings
- Parameter monitoring
- All required fittings and measuring instruments
- for configuration of the system
Operating conditions
The requirements for the water inflow to the DEMIN systems are listed below:
Inlet pressure | 2 – 6 bar |
Inlet temperature | 5 - 40° C |
TDS inlet | max. 500mg/l |
Inlet water | free of oil, oxidants, colloids and particles |
Note
We recommend the use of filtration to remove colloids and particles.
Product Leaflet
For further information and specification, please download our compact fact sheet.
Inatec-Demin
If you have any questions or requests, you can simply write to us using the form.