header 1

ROTEC - REVERSE OSMOSIS UNIT

The ROTEC C series comprises our compact reverse osmosis systems as wall-mounted devices.

ROTEC C

REVERSE OSMOSIS UNIT

The ROTEC C series comprises our compact reverse osmosis systems as wall-mounted devices. The systems are ideal for applications where small water volumes in good quality are needed. Besides the very short delivery period, the ROTEC C systems offer excellent quality and a high level of operating reliability.

ROTEC C

Features

  • Low energy consumption with high yield
  • Fully automatic reverse osmosis
  • Highly ef ficient membrane system
  • Completely preassembled
  • Space-saving wall-mounted installation
  • Reliable operating mode with product flow value monitoring
  • Simple start-up
  • Optionally available with pivoting frame or frame stand

Components

  • Plastic housing for wall-mounting 5 μm fine filter
  • Rotary vane pump
  • GRP pressure pipes
  • Reverse osmosis membrane
  • Parameter monitoring
  • Microprocessor control
  • All required fittings and measuring instruments for configuration of the system and control of hydraulic parameters

Operating conditions

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Temperature range 5 - 40° C
pH-range 2-11 continuously
  1-12 temporarily during cleaning
Colloid index (SDI 15) < 3
Permeate counterpressure max. 0,3 bar in complete stop
Free chlorine (Cl2) < 0,05 mg/l
Iron (Fe) max. 0,1 mg/l
Manganese (Mn) max. 0,05 mg/l
Product brochure

For further information and specification, please download our compact fact sheet.

Inatec Rotec C
Note

Further operating conditions are listed under the required operating conditions for reverse osmosis systems.

ROTEC L

REVERSE OSMOSIS UNIT

The ROTEC L reverse osmosis system covers large volumes of water: it can supply a broad bandwidth from 2.5 m³/h to 12 m³/h. We are happy to of fer systems with higher capacity on request..

ROTEC L

Features

  • Low energy consumption with high yield
  • Fully automatic reverse osmosis
  • Highly ef ficient membrane system
  • Completely preassembled
  • Reliable operating mode with product flow value monitoring
  • Simple start-up

Components

  • Stainless steel frame
  • 5 μm f ine f ilter
  • Vertical, multi-step high-pressure GPR pump
  • Pressure pipes
  • Reverse osmosis membrane
  • Parameter monitoring
  • Programmable logic control with remote monitoring and connection to control stations
  • All required f ittings and measuring instruments for conf iguration of the system and control of hydraulic parameters

Operating conditions:

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Temperature range 5 - 40° C
pH-range 2-11 during operation
  1-12 during cleaning
Colloid index (SDI 15) < 3
Permeate
counterpressure
max. 0.3 bar in complete stop
Free chlorine(Cl2) < 0,5 mg/l
Iron (Fe) max. 0.1 mg/l
Manganese (Mn) max. 0.05 mg/l

 

Product brochure

Learn more about all water treatment systems in our product folder

Inatec Rotec L

Note

Further operating conditions are listed in the mandatory operating conditions for reverse osmosis systems.

ROTEC M

REVERSE OSMOSIS UNIT

The ROTEC M series is a compact reverse osmosis system supplying water volumes of 250 to 1,500 l/h.
The systems are designed as standard frame systems, and they also of fer the possibility in confined
spaces to use a reverse osmosis system by virtue of their compact design.

ROTEC M

Features:

  • Low energy consumption with high yield
  • Fully automatic reverse osmosis
  • Highly ef ficient membrane system
  • Completely preassembled
  • Reliable operating mode with product flow value monitoring
  • Simple start-up

Components:

  • Stainless steel frame
  • 5 μm f ine f ilter
  • Vertical, multi-step high-pressure GPR pump
  • Pressure pipes
  • Reverse osmosis membrane
  • Parameter monitoring
  • Programmable logic control with remote monitoring and connection
    to control stations
  • All required f ittings and measuring instruments for conf iguration of the
    system and control of hydraulic parameters

Operating conditions:

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Temperature range 5 - 40° C
pH-range 2-11 continuously
  1-12 during cleaning
Colloid index (SDI 15) < 3
Permeate
counterpressure
< 0.05 mg/l
Free chlorine (Cl2) < 0.1 mg/l
Iron (Fe) max. 0.1 mg/l
Manganese (Mn) max. 0.05 mg/l

 

Product brochure

Learn more about all water treatment systems in our product folder

Inatec Rotec M

 

Note

Further operating conditions are listed in the mandatory operating conditions for reverse osmosis systems.

If you have any questions or requests, you can simply write to us using the form.