header 1

SOFTEC - Activated carbon filter system for dechlorination and fining

Our SOFTEC series is used primarily as a twin system in industry.

SOFTEC DSP EV

DUPLEX MONEX Softening Systems with single valves

Our SOFTEC DSP EV series is used primarily as a twin system in industry. Due to the large water volumes of up to 60 m³/h, the systems are equipped with single-valve controls.

2 Enthaertung SV

Features

  • Features:
  • Double sof tening system
  • Continuously soft water
  • Simple installation and commissioning
  • Programmable logic control
  • Automatic regeneration*

Components

  • GRP filter tank
  • Cation resin
  • Single valve control
  • Brine tank
  • Brine valve
  • Pipework including all required fittings and measuring instruments for conf iguration of the system and control of hydraulic parameters

Operating conditions

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Inlet temperature 5 - 40° C
Free chlorine (Cl2) < 0,1 mg/l
Iron (Fe) < 0,1 mg/l
Manganese (Mn) < 0,1 mg/l
Inlet water free of oil, oxidants, colloids and particles
Product brochure

For further information and specification, please download our compact fact sheet.

Inatec Softec DSP EV

 

Note

*For regeneration of the system, we recommend using pure salt for technical applications in tablet form, granulate or liquid brine.

 

SOFTEC DSP/DSP TWIN - ECOMIX

DUPLEX Softening Systems with additional de-ironing and demanganisation

Our SOFTEC DSP Ecomix water conditioning system is ideally suited for your well and household water pipe, as it
solves 5 problems in one sweep with one material. The ECOMIX material lowers the °dH, iron, manganin, TOC, and ammonium values by up to 98%. The systems can condition up to 12 m³/h water. The systems equipped with a CLACK central control valve are easy to install, programme and operate.

SOFTEC DSP ECOMIX TWIN

Features

  • Continuously soft water
  • Simple installation and
    commissioning
  • 9 freely programmable cycles
  • Automatic regeneration*

Komponenten

  • GRP filter tanks
  • 3-way reversing valve
  • ECOMIX
  • CLACK IA central control valves
  • Brine tank
  • Brine valve
  • Pipework including all required fittings and measuring instruments for configuration of the system and control of hydraulic parameter

Operating conditions

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Inlet temperature 5 - 40° C
Free chlorine (Cl2) < 4 mg/l
Iron (Fe) < 15,0 mg/l
Manganese (Mn) < 3,0 mg/l
Inlet water free of oil, oxidants, colloids and particles

 

Product brochure

For further information and specification, please download our compact fact sheet.

Inatec DSP/DSP Twin ecomix
Note

*For regeneration of the system, we recommend using pure salt for technical applications in tablet form, granulate or liquid brine.

 

SOFTEC DSP/DSP TWIN

DUPLEX Softening Systems

Our SOFTEC DSP series is a solution for providing sof tened water in private, commercial and industrial systems with output of up to 20 m³/h. The systems equipped with CLACK central control valves are easy to install, programme and operate.

SOFTEC DSP TWIN

Features

  • Double sof tening system
  • Continuously soft water
  • Simple installation and commissioning
  • 9 freely programmable cycles
  • Automatic regeneration*

Components

  • GRP filter tank
  • Cation resin
  • Central control valves
  • 3-way reversing valve
  • Brine tank
  • Brine valve
  • Pipework including all required fittings and measuring instruments for conf iguration of the system and control of hydraulic parameters

Operating conditions

Nachfolgen die Anforderungen an das Zulaufwasser der Anlagen:

Zulaufdruck 2 – 6 bar
Zulauftemperatur 5 - 40° C
Freies Chlor (Cl2) < 0,1 mg/l
Eisen (Fe) < 0,1 mg/l
Mangan (Mn) < 0,1 mg/l
Zulaufwasser
  free of oil, oxidants, colloids and particles

 

Product brochure

For further information and specification, please download our compact fact sheet.

Inatec DSP/DSP TWIN
Note
We recommend installing a filter, either a cartridge filter or self-cleaning filter with a filter unit of 100μm, upstream from the water softening system.

*For regeneration of the system, we recommend using pure salt for technical applications in tablet form, granulate or liquid brine.

 

SOFTEC MSP - ECOMIX

MONEX Softening Systems with additional de-ironing and demanganisation

Our SOFTEC MSP Ecomix water conditioning system is ideally suited for your well and household water pipe, as it
solves 5 problems in one sweep with one material. The ECOMIX material lowers the °dH, iron, manganin, TOC, and ammonium values by up to 98%. The systems can condition up to 12 m³/h water. The systems equipped with a CLACK central control valve are easy to install, programme and operate.

SOFTEC MSP

Features

  • Soft water during operation
  • Simple installation and commissioning
  • 9 freely programmable cycles
  • Automatic regeneration*

Components

  • GRP filter tank
  • ECOMIX
  • CLACK IA central control valve
  • Brine tank
  • Brine valve
  • Pipework including all required fittings and measuring instruments for configuration of the system and control of hydraulic parameters

Operating conditions

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Inlet temperature 5 - 40° C
Free chlorine (Cl2) < 4 mg/l
Iron (Fe) < 15,0 mg/l
Manganese (Mn) < 3,0 mg/l
Inlet water free of oil, oxidants, colloids and particles
Product brochure

For further information and specification, please download our compact fact sheet.

Inatec MSP ECOMIX
Note
We recommend installing a filter, either a cartridge filter or self-cleaning filter with a filter unit of 100μm, upstream from the water softening system.

*For regeneration of the system, we recommend using pure salt for technical applications in tablet form, granulate or liquid brine.

 

SOFTEC MSP

MONEX Softening Systems

Our SOFTEC MSP CV series is a solution for softened water in private and commercial systems with a capacity of up to 12 m³/h. Equipped with a CLACK central control valve, the systems are easy to install, programme and operate.

SOFTEC MSP

Features

  • Soft water during operation
  • Simple installation and commissioning
  • 9 freely programmable cycles
  • Automatic regeneration*

Components

  • GRP filter tank
  • Cation resin
  • CLACK IA central control valve
  • Brine tank
  • Brine valve
  • Pipework including all required fittings and measuring instruments for configuration of the
    system and control of hydraulic parameters

Operating conditions

The requirements for the water inflow to the systems are listed below:

Inlet pressure 2 – 6 bar
Inlet temperature 5 - 40° C
Free chlorine (Cl2) < 0,1 mg/l
Iron (Fe) < 0,1 mg/l
Manganese (Mn) < 0,1 mg/l
Inlet water free of oil, oxidants, colloids and particles
Product brochure

For further information and specification, please download our compact fact sheet.

Inatec SOFTEC MSP
Note
We recommend installing a filter, either a cartridge filter or self-cleaning filter with a filter unit of 100μm, upstream from the water softening system.

*For regeneration of the system, we recommend using pure salt for technical applications in tablet form, granulate or liquid brine.

 

If you have any questions or requests, you can simply write to us using the form.

Preferred way of contact?